High-Efficiency Custom Air Handling Units and Plug & Play Skids for Data Centers
Altop International delivers fully integrated, Eurovent-certified climate control solutions engineered for maximum uptime, extreme energy efficiency, and total operational security. From initial engineering design to Level 1–4 commissioning, we empower Colocation, Cloud, and Enterprise datacenters across Europe.
- 15+ Years Expertise
Datacenter Air Handling & Engineering - Eurovent Certified
T2/TB2 or TB1 Performance & Casing Quality - Full IT Cooling Chain
Fresh Air Units (FAU) to Fan Walls (FWU) - Turnkey Delivery
Engineering, FAT, Commissioning L1–L4 & Training
Uncompromised Uptime for Next-Generation Data Infrastructure
As data processing demands surge across Europe, modern datacenters require cooling infrastructure that combines high density, continuous reliability, and low Power Usage Effectiveness (PUE).
Altop International – as the exclusive partner of Euroclima – provides tailor-made climate systems designed specifically for mission-critical datacenter environments. We combine over 15 years of dedicated datacenter experience with high-tech manufacturing, delivering flexible Air Handling Units (AHUs), modular skid solutions, and pre-programmed datacenter software that perform flawlessly from day one.
Full-Spectrum Scope of Delivery
Design & Spatial Layout
Custom 3D CAD/BIM modelling and AirCalc++ engineering tailored to exact thermal and spatial room constraints.
Emergency Design & Redundancy
Fail-safe control architecture incorporating N+1 or 2N redundancies, rapid restart routines, integrated ATS, and UPS backup power (up to 60s) to ensure zero control downtime.
Modular Skid Units & Package Systems
Off-site manufactured, pre-wired, and pre-piped Skid execution combining Condensing Units (DX/KonAir), dehumidification, and humidification into Lift-and-Plug assemblies.
Plug & Play Integrated Controls
Factory-mounted control cabinets using premium Siemens Climatix, Rittal, and WAGO components. Pre-commissioned software loaded via SD card—no on-site programming required.
Factory Acceptance Testing (FAT)
Comprehensive, optional factory running tests prior to shipment, eliminating surprise risks on site.
On-Site Commissioning (Level 1–4)
Full-lifecycle site testing support:
- L1:Factory acceptance & component verification
- L2:Pre-commissioning & field quality audits
- L3:Functional performance testing
- L4:Integrated System Testing (IST) & handover
Data Center Software & Cloud
Advanced airflow, temperature, and humidity balancing routines with encrypted BACnet / Modbus, SC communication and optional remote predictive maintenance via Climatix IC Cloud.
Heavy-Duty Materials & C4/C5 Protection
Custom casing materials including high-grade stainless steel (AISI 304 / 316L) and C4 or C5 industrial corrosion coatings for aggressive environments.
Complete IT Cooling Chain: From FAU to In-Room FWU
1. Fresh Air Units / Outdoor AHUs (DOAS or FOH)
Fresh Air Pressurization, Free Cooling & Outdoor Conditioning
- Eurovent Certified ZHK INOVA Casing: 50 mm double-walled construction with non-flammable mineral wool insulation (150 kg/m³) delivering Class T2 thermal transmittance and Class TB2 or TB1 thermal bridging.
- Integrated Refrigeration (KonAir / DX):Coordinated inverter-controlled condensing units running on low-GWP refrigerants (R32 / R410A / or others) with zero site refrigerant piping requirements.
- Flexible Heat Recovery: Heat wheels, plate heat exchangers (up to 90% efficiency), or direct free cooling damper control.
- Robust Air Filtration:ISO Coarse to ePM1 filter walls with Filter Safe® leak-proof frames.
2. In-Room Fan Wall Units (FWU)
Precision Cooling Engineered Directly for Server Rack White Spaces
- Active PFC EC Fans:Ultra-low harmonic distortion (THD ≤ 5%) and power factor up to 0.998 for maximum electrical efficiency and grid compatibility.
- Service-Centric Mechanical Design:Hinged, easily removable EC fans, dual-side access doors, quick hydraulic couplings, and top-mounted pipe connections.
- Integrated PICV Valves:Pressure-Independent Control Valves ensure automated hydraulic balancing under variable load conditions.
- High Operational Density:Optimized footprint maximizing kW/m² cooling output inside the server room.
Proven Controls & Cyber Security
- Pre-Loaded Software:Control strategies pre-programmed and loaded via SD card. Simple configuration via display or local web server.
- Inter-Unit Balancing:Autonomous peer-to-peer communication between AHUs balances airflow, temperature, and humidity without single-point-of-failure master controllers.
- Encrypted Cyber Security:Native BACnet SC (Secure Connect), BACnet IP, Modbus IP/RTU, and LON interfaces for encrypted BMS integration.
- Predictive Maintenance Cloud:Climatix IC Cloud access for trend logging, early fault detection, and automated alerts to reduce maintenance overhead.
Why Builders Partner with Altop International
- Eurovent Certified Quality:Independently tested mechanical strength (D1), air leakage (L1), filter bypass (F9), and thermal metrics (T2/TB2 or TB1).
- Off-Site Assembly & Skids:Reduced installation time, minimized on-site trade coordination, and accelerated time-to-market.
- 15+ Years Track Record:Field-proven in hyperscale, colocation, bare metal, and cloud datacenters across Europe.
- Dedicated Engineering Crew:High-knowledge team supporting design consultants and MEP contractors at every phase.
- Tailored Materialization:Standard galvanized steel to C4/C5 anti-corrosion protection and AISI 316L stainless steel.
- Technical Innovation:Direct connection with Euroclima facilities ensures rapid adoption of cutting-edge technology.
Certified Quality & Environmental Compliance
- Eurovent Certified (ZHK)
- ISO 9001:2015 Quality
- ISO 14001:2015 Environment
- ISO 45001:2018 Safety
- VDI 6022 & DIN 1946-4
- Ecodesign ErP Compliant
Accelerate Your Data Center Project with Altop International
Need technical advice, custom CAD selections, or a quotation for your next datacenter build or expansion? Our data center specialists are ready to support your engineering team:
So let’s get in touch and discuss:
- Design and requirements
- Supply air temperature
- Humidity control
- Redundancy (N, N+1, 2N)
- Energy efficiency
- Pressure control
- Integration with data center cooling
- Monitoring and BMS integration
- Commissioning and training